Bathroom Fan Automation — Using Humidity Data to Decide Whether to Upgrade

30- and 60-minute ventilation with a SmartThings switch and humidity sensor

Comparing the Himpel Turbo 747 FZA-70S1 and Flex C2-100LF(MD), and planning SmartThings automation and humidity measurements before replacing a bathroom fan.

I decided to use the bathroom exhaust fan more often to reduce mold in the bathroom.

Whenever I left the fan running, I had to go back to the bathroom later to turn it off. It was a small inconvenience, but I think it kept me from using the fan as much as I should have.

At first, I considered replacing the existing fan with a more powerful one. But I wanted to find out whether the fan itself was inadequate or whether I simply had not been running it enough.

The existing fan and a possible replacement

My current exhaust fan is a Himpel Turbo 747 FZA-70S1. It comes with a magnetic backdraft damper.

The replacement I looked into is the Flex C2-100LF(MD) from the same manufacturer.

SpecificationTurbo 747 FZA-70S1Flex C2-100LF(MD)
Listed airflow70 m³/h90 m³/h
Static pressure categoryMediumMedium
DamperMagneticMotorized
Duct diameter100 mm100 mm
Ceiling cutout125–165 mm165 ± 5 mm

The Flex has a listed airflow about 29% higher than my existing fan and includes a motorized damper. If the ceiling opening and the space above it are compatible, it may also be possible to install it without major construction work.

However, my existing fan still works normally, and I do not yet know how much ventilation would improve in my bathroom.

Rather than replacing the fan immediately, I decided to change how I use the one I already have.

Product specifications: Himpel Turbo 747 FZA-70S1 · Himpel ventilation system catalogue · Himpel Flex C2-100LF(MD)

Automatically turning off the fan with a smart switch

I plan to use a two-gang smart switch that can control the bathroom light and exhaust fan separately.

The light will work as usual, while only the exhaust fan will have an automatic shutoff.

My plan is to set the fan to switch off after 30 minutes by default. That should remove the inconvenience of having to go back to turn it off.

The idea is to be able to ventilate the bathroom for a set period simply by pressing the fan button on the way out.

Before installation, the switch needs to be checked for compatibility with the fan's motor load and the existing wiring, not just the lighting circuit.

Adjusting ventilation time with a humidity sensor

I also decided to make use of a humidity sensor I already own.

Humidity in the bathroom can be quite different after a shower compared with ordinary use. Rather than ventilating for the same 30 minutes every time, I thought it would be more effective to adjust the duration according to the humidity.

I plan to configure the SmartThings automation as follows:

  • Run the fan for 30 minutes by default after it is switched on.
  • Check the bathroom humidity after 30 minutes.
  • If humidity is below 70%, turn off the fan.
  • If humidity is 70% or higher, run it for another 30 minutes.
  • Turn it off after a total of 60 minutes, regardless of humidity.

The key is to decide whether more ventilation is needed based on humidity after 30 minutes of ventilation, rather than at the moment the fan is turned on.

The 70% threshold is a starting point. I plan to adjust it based on the bathroom's usual humidity and the changes I observe after ventilation.

Using humidity data to evaluate the existing fan

Another benefit I expect from this automation is the ability to assess how well my existing fan ventilates the bathroom using data.

I would like to examine the following using humidity readings and fan activity recorded in SmartThings:

  • Normal bathroom temperature and humidity
  • Temperature and humidity immediately after a shower
  • Humidity changes in 10-minute intervals after the fan starts
  • Humidity after 30 and 60 minutes of ventilation
  • Time needed to return to the usual humidity level
  • Whether humidity rises again after the fan switches off

I will also need to account for shower duration, whether the bathroom door is open, and seasonal differences in temperature and humidity. I intend to collect data several times under conditions that are as similar as possible.

A humidity sensor cannot directly measure the fan's actual airflow or static pressure, but it can provide an indirect indication of how effectively the bathroom is being dried.

There is no need to replace the fan just yet

If the humidity falls to a stable level after 30 to 60 minutes of ventilation with my existing fan, I may not need to replace it at all.

On the other hand, if humidity remains high despite adequate ventilation time, I plan to check the incoming air path and the exhaust duct before considering a fan with higher airflow and static pressure performance.

If I do replace the fan, I would like to collect humidity data again under the same conditions and compare the results before and after the upgrade.